METODE ALTERNATIF ANALISIS INSEKTISIDA PERTANIAN DELTAMETHRIN MENGGUNAKAN KROMATOGRAFI CAIR KINERJA TINGGI PENGGUNAAN KOLOM C-18, FASE GERAK ASETONITRIL 80% DALAM AKUABIDES, LAJU ALIR FASE GERAK 1,6 ML/MENIT, DAN PANJANG GELOMBANG DETEKTOR UV-VIS 190 NM (ALTERNATIVE METHOD OF FARMING INSECTICIDE - DELTAMETHRIN ANALYZES USING HIGH PERFORMANCE LIQUID CHROMATOGRAPHY USE OF COLUMN C-18, MOBILE PHASE ACETONITRILE 80% IN AQUABIDEST, FLOW RATE OF MOBILE PHASE 1.6 ML/MINUTE, AND WAVELENGHT OF UV-VIS DETECTOR 190 NM

R. Gagak Donny Satria, Bambang Sumiarto, Andi Trisyono, Agustina Dwi Wijayanti

Abstract


Deltamethrin is a common pesticide used in plants and animals. Research about this pesticide has been done with various methods. The purpose of this research was to validate the alternative test method of deltamethrin using High Performance Liquid Chromatography (HPLC). This research used pure deltamethrin. The tool in this research was HPLC Shimadzu 6.1 with 80% acetonitrile in aquabides for mobile phase, flow rate 1.6 ml/min and uv-vis detector wavelength 190 nm. The data were analyzed by calculated the average, standard deviation, and relative standard deviation. The results showed the average area for each concentration of 0.1 ug/ml, 0.25 ug/ml, 0.3 ug/ml, 0.5 ug/ml, 0.75 ug/ml, 1 ug/ml,2 ug/ml, and 5 ug/ml, were 52806.33, 119070.3, 137758.3, 220292, 339677.3, 449448.7, 856049.3, and 2,177,558, with a linear equation y = 43283x + 8455, R = 0,999. It could be concluded that the method is valid based on precision, acuration, specificity, limit of detection, limit of quantification, and linearity.

Keywords: deltamethrin, HPLC, validation


Full Text:

PDF

References


Ahuja, S. dan Dong, M.W. 2005. Handbook or Pharmaceutical Analysis by HPLC. Elsevier Inc, Amsterdam. Hal : 197-207.

Gilbert, S. G. 2012. A Small Dose of Toxicology The Health Effects of Common Chemicals 2nd Edition. Healthy Word Press, United States. Hal : 80-85.

Harmita. 2004. Petunjuk Pelaksanaan Validasi Metode dan Cara Perhitungannya. Majalah Ilmu Kefarmasian, Vol. I, No.3. Desember : 117-135.

Johnson, E.L. dan Stevenson, R. 1991. Dasar Kromatografi Cair. Penerbit ITB, Bandung. Hal : 1 8.

Kim K.B., Bartlett M.G., Anand S.S., Bruckner J.V., Kim H.J. 2006. Rapid Determination of The Synthetic Pyrethroid Insecticide, Deltamethrin, in rat Plasma and Tissues by HPLC. Journal of Chromatography B 834 : 141 148.

National Pesticide Information Center. 2012. Deltamethrin. Diakses pada http://www.epa.gov/pesticides/deltamethrin. [2 desember 2012].

Rohman, A. 2009. Kromatografi untuk Analisis Obat. Graha Ilmu, Yogyakarta. Hal : 111-234.

Satria G.D., Wijayanti, A. D., Wikan, P., Nurul, A., Prana, D., Acintya, R. 2011. Chromatogram Analysis to Detect The Deltamethrin Added in The Muscle of Chicken Using The High Performance Liquid Chromatography. Proceding International Advance Technology on Veterinary and Life Scientist. Universitas Gadjah Mada: Yogyakarta. Hal : 313 318.

Snyder, L.R., Kirkland, J.J., and Glajch, J.L. 1997. Practical HPLC Method Development, 2nd Ed. John Wiley & Sons, Inc, New York. Hal : 691-693.




DOI: https://doi.org/10.55259/jiip.v17i1.330

Web Analytics Made Easy - Statcounter View My Stats